The vast majority of decontamination work is performed by Vapor Phase. The JPX is injected
directly into the purge stream that is used in the normal steam out process during shutdowns. The
JPX is carried throughout the column contacting all surfaces, breaking down the hydrocarbons
into lighter ends that are carried overhead to the flare system and emulsifying the heavier
hydrocarbons to be drained from the column with the condensate.
This Vapor Phase process greatly reduces decontamination time, wastewater generation, and
chemical cost, but provides H²S, Benzene LEL removal, so that the equipment is ready to enter
after a cool down water flushing rinse.
JPX/JPX-E can be applied by circulation to target packed beds that may be more heavily
contaminated or be at risk from Iron Sulfide, pyrophoric materials. Typical circulation solution
concentrations are from 1% to 3%.
A third application type would apply to horizontal vessels that have known sludge
accumulations, such as desalters or gas recycle KO drums.
The vessel is typically filled to 1/3 level and JPX/JPX-E is added to the steam heated water. The
mix is boiled and agitated to provide maximum sludge liquid content. The sludge hot water
slurry is then pumped out of the vessel and the vessel is re-steamed to relief to purge all vapors
in preparation for entry.
An auxiliary step when pyrophoric material is suspect of being present is to add JPX-EE (a mild
oxidizer and solubilizer) to the rinse water; this neutralizes the pyrophoric iron sulfides and
allows them to be rinsed from the internals of the columns.
Friday, January 30, 2015
Monday, November 17, 2014
Struvite Removal Wastewater Lab Testing
We at Jayne Products ask for and receive a great variety of struvite samples as can see in the picture below.
Struvite and Vivianite can range in color, granularity, hardness, composition as well as other variables.
We offer those with struvite problems free testing on their different samples to prove our products effectiveness.
Our testing typically takes into account the comparison of the struvite to others we have collected so we can asses if will need a stronger concentration dependent upon the amount of struvite.
We also do product testing were we will place 5 grams of struvite in different solutions, 100%, 50%, 30%, 25% and so forth in a beaker with a magnetic stirrer (to resemble a recirculation).
Below is an example of our testing setup. For more information, to contact us or for free samples please visit our website.
Tuesday, May 13, 2014
JPX Chemical Cleaning Set-Up Procedure
Below are both the diagrams for the set up as well as the video to set up for use of JPX line of products into vessels for cleaning.
Please don't hesitate to call us for any help or consultation regarding the use of JPX or the procedure to set up!
Tuesday, March 18, 2014
Struvite Removal Wastewater Removal Egg Demo
Our Struvite Removal and Control Product is used primarily in wastewater applications, including both municipal and CAFO operations.
In this video you will notice an Egg is placed in enough Struvite Remover to keep it submerged. The pH of this product is approximately 0.5 but since it is a buffered acid, it has been proven to be:
Non-corrosive to steel
Only Slightly irritating to skin
Meaning, that despite its low pH, and being a great descaler, it is safe, as well as will not damage any equipment in your operation.
The egg in the video proves that it will remove and dissolve scale (egg shell), while not harming the protein (egg), leaving it fully intact and handling both the product and the egg with our bare hands.
For any other questions, information, or for a FREE product sample and consultation please visit our websites.
http://jayneproducts.com/applications/wastewater
http://www.struviteremoval.com
Friday, January 24, 2014
Turnaround and Shutdown Decontamination Chemical Cleaner
JPX is the most cost effective
decontamination chemical available. It outperforms well-known and more
expensive products. JPX injection into your vessel steam out will:
·
Cut steam out time by 2/3
·
Remove hydrocarbons, H²S and benzene, permitting
earlier vessel entry
·
Eliminate internal clean-ups normally required for
inspection and repair
·
Reduce the time required for exchanger bundle
cleaning
JPX is safe for people, the effluent system, and air quality.
JPX has been used in cokers, crude and vacuum units, FCC, hydrotreaters,
hydrocrackers, reformers, contactors, separators, and all varieties of columns:
·
See our steam injection or circulation diagrams for
an outline of the JPX cleaning process.
Shell, BP, Arco, Mobil, Chevron, ConocoPhillips, Tesoro, and overseas
refineries have saved money by utilizing JPX to decrease down time.
Wednesday, January 8, 2014
Vapor Phase Application of JPX and JPX-E Chemical Cleaner
Vapor Phase Application of JPX and JPX-E
Preparatory:
Obtain simplified process flow
diagram review; with operations, the sequence and priority for equipment
decontamination. Mark up diagram to show
JPX injection points and vent locations; show flow path for vapor cleaning
through process vessels.
Prepare a layout page showing
sequence and volumes of JPX (or JPX-E).
Time, temperature, results, and rinse columns will be completed as
application proceeds.
Application:
Prior to pumping JPX, verify the following, by physically checking:
1) Vessel is drained – Condensate not hydrocarbon coming from bottom drain
connection. Do not rely on control
instrument levels. They may be plugged
or blocked in.
2) Vessel is vented to relief system, sometimes called blowdown or vapor
recovery system.
3) JPX injection valves into vessel are open, and that only one flow path
for JPX exists.
4) Check and record vessel temperature.
Depending on system flow and vessel size, temperature should be over
200°F after a couple of hours of steaming.
5) Check rinse line (reflux line) to be free of H.C. and hot via steam.
Begin pumping JPX
into vessel:
Typically one drum per 20 minutes.
After pumping ½ of the calculated JPX required, re-check drain line, any
top vent connection and reflux (rinse) line for JPX lemon odor to verify
vaporization is adequate. When
completed, JPX injection continue steaming for several more hours; then have
operations lower steam rates dropping vessel pressure and perform sniff for
LEL, benzene, and H2S. If
vessel is a column, the overhead accumulator would have JPX injected
immediately after column JPX injection and would be sniffed at the same time as
column.
If sniff OK, start fresh water rinse, hot water is preferred. Maximize flow of rinse & continue for
several hours until bottom drain is clear of soap emulsion. Caution, do not use accumulator water or
reflux pump as water rinse source.
Accumulator may have sludge emulsion from JPX cleaning and could
recontaminate column.
After:
Complete layout
page info and discuss with operations.
Flush JPX pumps with water.
Remove empty JPX drums to location for later pick up.
Thursday, December 26, 2013
Oil Refinery Chemical Cleaning, Why JPX over the competitors?
Why JPX over the competitors?
JPX provides superior performance in these areas:
JPX will emulsify more oil and carry it out of the
equipment. Testing by major US oil companies
verifies this.
JPX will rinse off the surface of equipment and leave no
sticky film like some competitors.
JPX will permit separation of the emulsion into oil and
water phases within a shift which permits oil recovery and water disposal to
effluent systems in a very timely manner.
JPX is applied in the majority of applications by vapor
phase system injection. This eliminates
the need for dozens of contractors as used by the competition. We can apply the product with two people or
train your local contractors or operators to handle all phases of application,
rinse and recovery.
Our fifteen years of experience with the application of JPX
allows us to quickly propose the most effective procedures whether it be vapor
phase or circulation for vessel, exchanger or desalter cleanouts.
We work with operations to mark up drawings for injection
points, circulations, vent and drain points.
We will provide simple procedures that will be seamlessly integrated
into the shutdown process.
Our cost proposals will include technical and applications
support with labor as required. We are
very confident that your cost will be much lower than our competitors and your
results will be better by utilizing JPX.
For more information, free product sample, and consultation visit JPX decontamination chemical cleaner page
For more information, free product sample, and consultation visit JPX decontamination chemical cleaner page
Subscribe to: